| Input Voltage: | 120 V AC |
| Height: | 4.5" |
| Output Voltage: | 120 V AC |
| Output Receptacles: | 2 x NEMA 5-15R |
| Product Type: | Isolation Transformer |
| Input Receptacles: | 1 x NEMA L5-15P |
| Brand Name: | Tripp Lite |
| Additional Information: | Transformer Type: Medical grade, low impedance transformer-based line isolation transformer Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode Suppression Joule Rating: 680 (510 input/170 output) Leakage Current: As low as 100 microamps Noise Suppression Rating: 35 to 65 DB Total Harmonic Distortion: Less than 1% Over Current Protection: 2A circuit breaker Cooling Method: Convection Efficiency: 96% Let-through Voltage (Ring Wave): L-N: 20 V L-G: 20 V N-G: 0.5 V Let-through Voltage (Combination Wave): L-N: 250 V L-G: 250 V N-G: 0.5 V |
| Manufacturer: | Tripp Lite |
| Manufacturer Part Number: | IS250HG |
| Maximum Line Current: | 2.10 A |
| Product Model: | IS250HG |
| Certifications & Standards: | cUL UL 2601-1 UL (UL Series AGIS250YWN) |
| Marketing Information: | Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE |
| Form Factor: | Tower |
| Limited Warranty: | 2 Year |
| Product Name: | Isolator IS250HG Isolation Transformer |
| Width: | 4.8" |
| Depth: | 7.8" |
| Power Rating: | 250 VA |
| Package Contents: | IS250HG IS250HG Isolation Transformer Instruction manual with warranty information |
| Manufacturer Website Address: | http://www.tripplite.com |