| Nonturn Device Radius | 0.625 inches nominal |
| Thread Series Designator | unef |
| Switch Location And Position Designation | internal at pole two |
| Thread Quantity Per Inch | 32 |
| Test Data Document | 10001-3179574 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) |
| Center To Center Distance Between Terminals Parallel To Length | 0.906 inches maximum |
| Switch Current Rating And Type In Amps | 0.5 ac and 0.5 dc |
| Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 300.0 ac all locations |
| Reset Method | manual |
| Nonturn Device Diameter | 0.180 inches minimum and 0.300 inches maximum |
| Circuit Protection Type | overcurrent all locations |
| Pole Quantity | 2 |
| Manual Actuator Type And Quantity | 1 toggle |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Actuator Function | trip-reset |
| Operating Voltage Type And Rating Per Pole In Volts | 240.0 ac all locations |
| Body Length | 1.562 inches maximum |
| Fragility Factor | moderately rugged |
| Trip Release Method | magnetic all locations |
| Actuator Position Designation | between pole one and two |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 all locations |
| Case Material | plastic |
| Main Contact Tripping Mechanism Type | trip free |
| Inclosure Protection Type For Which Designed | vibration resistant and moisture resistant and shock resistant and fungus resistant and salt spray proof |
| Switch Terminal Type | pin |
| Trip Release Characteristic | time delay all locations |
| Unpackaged Unit Weight | 3.600 ounces |
| Frequency In Hertz | 400.0 all locations |
| Switch Voltage Rating And Type In Volts | 120.0 ac and 50.0 dc |
| Nominal Thread Size | 0.375 inches |
| Terminal Type And Quantity | 4 wire hook |
| Nonturn Device Location | at 12 oclock |
| Bushing Length | 0.280 inches minimum and 0.380 inches maximum |
| Mounting Surface To Terminal End Distance | 1.828 inches maximum |
| Body Width | 1.937 inches maximum |
| Special Handling Feature | magnetic |
| Center To Center Distance Between Terminals Parallel To Width | 0.687 inches nominal |
| Auxiliary Switch Function And Quantity | 1 alarm |
| Switch Contact Arrangement | single pole, double throw |
| Body Style | multipole-single actuator type |
| Trip Delay Time In Seconds Per Rated Continuous Current | 0.200 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations |
| Maximum Continuous Load Current Rating Per Pole | 10.0 amperes ac all locations |
| Storage Type | general purpose warehouse |
| Internal Trip Release Configuration | series trip all locations |