| Thread Quantity Per Inch | 32 |
| Thread Series Designator | unc |
| External Actuator Linkage Arrangement | one, two, and three linked |
| Center To Center Distance Between Terminals Parallel To Length | 1.928 inches minimum and 1.948 inches maximum |
| Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 ac all locations |
| Reset Method | manual |
| Circuit Protection Type | overcurrent all locations |
| Manual Actuator Type And Quantity | 3 toggle |
| Pole Quantity | 3 |
| Mounting Facility Type And Quantity | 6 threaded hole |
| Actuator Function | trip-reset |
| Operating Voltage Type And Rating Per Pole In Volts | 240.0 ac all locations |
| Body Length | 2.490 inches minimum and 2.510 inches maximum |
| Fragility Factor | moderately rugged |
| Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 inches minimum and 0.760 inches maximum |
| Trip Release Method | magnetic-hydraulic all locations |
| Actuator Position Designation | at each pole |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 all locations |
| Case Material | plastic |
| Main Contact Tripping Mechanism Type | trip free |
| Ultimate Trip Time Per Pole In Seconds | 9.000 minimum all locations and 120.000 maximum |
| Inclosure Protection Type For Which Designed | fungus resistant and moisture resistant |
| Boss Height | 0.130 inches minimum and 0.150 inches maximum |
| Trip Release Characteristic | time delay all locations |
| Frequency In Hertz | 60.0 all locations |
| Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 inches minimum and 2.072 inches maximum |
| Nominal Thread Size | 0.138 inches |
| Terminal Type And Quantity | 6 threaded stud |
| Mounting Surface To Terminal End Distance | 2.461 inches minimum and 2.481 inches maximum |
| Body Width | 2.490 inches minimum and 2.510 inches maximum |
| Center To Center Distance Between Terminals Parallel To Width | 0.740 inches minimum and 0.760 inches maximum |
| Body Style | 8c multipole-multiple actuator type |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct and 0.300 minimum at 400 pct and 2.000 maximum at 400 pct |
| Arc Quenching Method | magnetic blowout |
| Maximum Continuous Load Current Rating Per Pole | 15.0 amperes ac all locations |
| Storage Type | general purpose warehouse |
| Internal Trip Release Configuration | series trip all locations |